Aquapump XL Duo, GTF 1200-S1, Subm. pressure switch

Aquapump XL Duo, GTF 1200-S1, Subm. pressure switch

The pumping station without sewage wastewater is equipped with one or two submersible pumps and a backflow preventer. The collection tank made of permanently resistant polymer (PE) has an open pump tank with universal connection options.

*Maximum safety

*Flexible installation

*Also handles large quantities of wastewater

*Item no.  8743012

*GTIN 4026092075661

*Price group     60

Açıklama

Quick-release closures enable the integrated components to be removed easily. The KESSEL modular system provides different engineering chamber options as accessories for the further layout.

 

Variant

Note on installation depth: in combination with a chamber module

Type of system: duo pump

Shut-off valve: without shut-off valve

Passage seal for conduit pipe (DN): 100

Access steps: yes

Passage seal for ventilation pipe (DN): 100

Installation: Wet installation

Pump control: Control unit

Backflow preventer: integrated

Pressure pipe connection: horizontal

 

General characteristics

Colour: black

Standard: EN 12050-2

Type of wastewater: without sewage

Installation situation: underground installation

Delivery state: Pre-mounted for final assembly on site (pumps and sensor system must be fitted on site and control unit must be connected)

System type: Duo

 

Dimensions

Net weight: 105 kg

Gross weight: 123 kg

Groundwater resistant from lower edge of base section: 3000 mm

Length: 1330 mm

Width: 1240 mm

Height: 914 mm

Packaging dimension: length: 1300 mm

Packaging dimension: width: 1300 mm

Packaging dimension: height: 1050 mm

 

Tank/drain body

Pressure pipe connection (DN): 32

Pressure pipe connection (OD): 40 mm

Distance from centre of outlet pipe to tank bottom: 780 mm

Distance pipe bottom inlet to tank bottom: 607 mm

Distance from centre of inlet pipe to tank bottom: 687 mm

Distance from inlet pipe invert to top of tank: 281 mm

Inlet max. scoring (DN): 150 mm

Inlet nominal size (OD): 160 mm

Inlet nominal size (DN): 150 mm

Number of inlets: 1

Clear width of tank (LW): 1000 mm

Pumping volume: 100 l

 

Pumping device

Pump: GTF 1200

Number of pumps: 2

Weight, pump: 10 kg

Connection type: coded plug

Operating voltage: 230 V

Protection class: I

Insulation class: F

Cos phi – power factor: 0,98

Protection class (pump): IP 68 (3m)

Temperature monitoring: integrated

Max. temperature (permanent) of conveyed material: 40 °C

Max. pumping capacity: 15,5 m³/h

Max. pumping height: 9 m

Speed: 2650 U/min

Power P1: 1,4 kW

Power P2: 0,84 kW

Operating mode: S1

Type of pump connection cable: H07RN-F 3G 1.5 mm²

Impeller type: Multi-vane impeller

Length of mains cable for pump: 10 m

Rated current: 6,2 A

 

Control

Control unit: Comfort

Alarm sensor: optical probe

Level measurement instrument: Submersible pressure switch

Type of level measurement: pneumatic

Protection class control unit: IP 54

Mains frequency: 50 Hz

Operating voltage: 230 V

Connection type: coded plug

Length of mains cable for control unit: 1,4 m

Potential-free contact: optional

GSM interface: yes

USB interface: yes

Log book function: yes

Multi-line display: yes

Battery buffering: yes

Self-diagnosis system (SDS): yes

Type of fuse required (electrical protection): C 16 A